VPM-07
PHASE SELECTOR
ㆍ Equipment that supplies power 1 Phase 220VAC, 5A, 50Hz, receiving voltage 3 Phase 380VAC, 4 Wire.
ㆍ In the event that one phase voltage is missing or 2 Phase is missing, VPM-07 will select the remaining phase voltage to supply to the system continuously at Output 2 Load.
ㆍ There are 2 Outputs for supplying power to Shunt TRIP and connecting other loads.
ㆍ There are 2 models to choose from. VPM-07-1 is a model that connects to use Phase Protection Relay from outside and
VPM-07-2 is a model that has a built-in Phase Protection check.
ㆍ Phase Protection Relay Function for protecting against power failure - overload, phase unbalance and phase switching (VPM-07-2) by working status notified at LED OUT3 and Relay Output 3
HM-007
Wireless Humidity & Temperature Transmitter
ㆍ Wireless temperature and relative humidity measurement device. Send data to the computer up to 500 m. indoors and 1000 m. outdoors.
ㆍ Can install more than 1000 units per 1 Gateway system.
ㆍ LoRaWAN Class A wireless communication
ㆍTemperature measurement range 0-100C
ㆍHumidity measurement range 0-100% RH
ㆍDisplayed with 3-digit 7-Segment LED.
Model: TGA-004B, Brand: PM
Features
• A device for measuring and displaying temperature and humidity values, receiving signals from the Humidity & Temperature Transmitter Model HM-006N-00
• Displays information on a 7-Segment screen of 2.3 inches and 4 inches, with 4 digits in 2 rows, providing clear visibility
• Equipped with an Alarm Relay Output with 2 Contacts rated at 5A 250VAC/5A 30VDC (NO,NC)
• Displays an underscore symbol in cases where the Humidity & Temperature Transmitter malfunctions
• Communicates with computers via RS 485, using the MODBUS protocol
• Includes mounting loops for installation purposes
Model: PMV320N,Brand: PM
DESCRIPTION
• Cooling fan for electric cabinet with filter to filter dust into electrical cabinet, control cabinet.
• Wind power at 31-927 m3/h with several sizes
• Time saving with Clips Lock and maintenance with design flap - Open Fan for Pulling Mask Easy to replace dust filter.
• The shape is designed to be beautiful and thin, the installation is smooth to the surface of the cabinet.
• Both air in lot and wind out 2 type of filter fans : blow in, blow out
• IP 55 standard
OPERATION
Cabinet Filter Fan is a cooling fan for electric cabinets, cabinets, refrigerators. Both models are air lnlot and wind out by being designed to be beautifully shaped and thin. The installation is smooth with the surface of the cabinet (Example A)
And in the installation. Easy to install, fast and strong with Clips - Lock with proper design. Use flexible plastic material. Do not use the same with the case of the fan, which is hard not suitable for adhesion. Fan does not vibrate at work (Example B)
To change the dust filter. It’s easy. With the design of Flap - Open by simply pulling out the mask to replace the dust filter.And push the mask back original (Example c)
Fittings spring Terminals make the cable wiring easy and fast - (Example D)Typically, the heat transfer characteristics. Hot air will float from bottom to top. Fan Cabinet Filter Fan should be installed at the top of the cabinet. There is a mask with a dust filter attached to the bottom to allow air from the outside into the cabinet (Example E)
Model: TM-012-Series,Brand: PM
DESCRIPTION
• Conveting Devices Thermocouple, RTD (PT100) and Resistance standard 4-20 mA analog signal
• The Input Type of Thermocouple and Range can be programmed
• Compatible with Thermocouple and Skull RTD (PT100) type
• Compact size Installed to the skull (Bulb)
OPERATION
TM-012P Thermocouple, RTD (PT100) and Resistance Transmitter is convert signal from Thermocouple, RTD (PT100) and Resistance to standard 4-20 mA analog signal for input to PLC, Process Controller or other peripherals
Input can be selected program. Thermocouple Type K, J, E, N, R, S T Include Range of Thermocouple, RTD (PT100) and Resistance using Progrmmable Module RM-TM-012P and Software or choose to specify the type of thermocouple and measurement area. Thermocouple, RTD (PT100) and Resistance as needed
Suitable for remote wiring because it is a 4-20 mA Current Loop is small, compact, can be inserted into the Bulb, thus saving installation space. By the way Thermocouple, RTD (PT100) and Resistor Sensor with Transmitter are the sam Unit without isolation with Transmitter
Model: RHM-006-00,Brand: PM
• Temperature and Relative humidity equipment together and convert the temperature
and relative humidity signals into standard electrical signals (Output)
- DC Current 4 - 20 mA
- DC Voltage 0 - 10 VDC
- RS-485 (Modbus RTU Protocol) Baud rate 2,400, 4,800, 9,600, 19,200, 38,400
• Temperature measurement range 0 - 100 C
• Relative humidity measurement range 0 - 100% RH
• Long axis 2 sizes structure (Probe axis made from stainless)
- Long axis 300 mm
- Long axis 500 mm
• Suitable for installation temperature and relative humidity inside the oven up to
100 ํC, disinfection tanks, dehumidifiers, etc. By inserting the hole into the cabinet,
the skull is located outside the cabinet, which has an internal electronic circuit.
It can be used with a thermostatic oven
• There is a probe tip on the silicon carbonate filter to protect the dust and mounting
flange for mounting
Model: HM-006N-00 ,Brand: PM
Description
ㆍTemperature and Humidity measurement in one device. It converts
temperature and humidity signal to standard electrical signal (Output).
- DC Current 4-20 mA.
- DC Voltage 0-10 VDC
- RS-485 (Protocol RTU Modbus)
Baud Rate : 4800, 9600, 19200, 38400 bps
ㆍ Temperature measure range 0-100 *C.
ㆍHumidity measure range 0-100% RH.
ㆍSuitable to install on ceiling or inside room.
ㆍCan install dust and water stream area.
DESCRIPTION
• Digital timer switch with 2 types of alarm setting : Daily Weekly
• Accessories to set up the variables and show the values on computer or smartphone by using Wi-Fi
• Copy the program and press to other devices
• Program On/offf setting to control electrical equipment for 30 days and 10-time periods
• Time relay setting : second, minute, hour, day, month, year.
• Program memories of 99-setting time, Om/off cycle time adjustment
OPERATION
SMW is a timer or Digital time switch Used for timer It is suitable for work requiring control of work time. Can be set up-turn off electrical equipment. The time required or set to run a Recycle Timer
Can be a holiday program 30 days advance and 10 vacation periods. Output can also be manually set ON/ OFF. In case of power off Clock signal SMW continues to count. No need to set a new time or program
Display with OLED Display can be seen clearly. OLED time cannot be set when the keypad is not pressed. Available time display is either AM/PM or 24 hours
| Company name | Primus Co.,Ltd. | Website URL | https://www.primusthai.com/ |
|---|---|---|---|
| Street address |
Khlong Nueng, Khlong Luang Pathum Thani Kingdom of Thailand
[See map] |
Person in charge | Porameth Inkaew |
| Telephone number | +66-87-307-4662 | Fax number | +66-2-147-4206 |
| Capital | 90,000,000 THB | Employees | Unregister |
| Annual sales | Unregister | EMIDAS Member Number | 103172 |
| Main 3 products |
|
||

Primus Co.,Ltd.